Customs formalities for the import of goods subject to tax
Skip the table of contentsImport of products containing fluorinated gases
In the case of imports of products containing fluorinated gases, the declaration shall be made in the same manner as in the previous point, with the exception that, where the weight in kilograms of the pure fluorinated gas or mixture contained in the imported product is unknown, it shall be presumed, unless proven otherwise, that the quantity of gas contained therein is as follows:
- Domestic refrigerators and freezers: 0.250 kilograms per unit of cooling capacity expressed in kW.
- Industrial cold stores and commercial refrigeration installations: 1.5 kilograms for every unit of cooling capacity expressed in kW.
- Industrial cold stores and commercial freezing facilities: 2.5 kilograms per unit of cooling capacity expressed in kW.
- Portable air-conditioning units: 0.250 kilograms per unit of cooling capacity expressed in kW.
- Refrigeration equipment for building air-conditioning systems, heat pumps and dehumidifiers: 0.500 kilograms for each unit of cooling capacity expressed in kW.
- Air conditioning for passenger cars: 0.600 kilograms per vehicle.
- Air conditioning for vans, lorries and forklift trucks: 1 kilogram per vehicle.
- Air conditioning for caravans, motorhomes and special-purpose vehicles: 2 kilograms per vehicle.
- Air conditioning for buses or coaches: 5 kilograms per vehicle.
- Aerosol cans with a total capacity of 250 millilitres or less: 0.125 kilograms per can.
- Aerosols with a total capacity of 500 millilitres or less, but more than 250 millilitres: 0.250 kilograms per container.
- Aerosols with a total capacity of more than 500 millilitres but not exceeding 1,000 millilitres: 0.5 kilograms per container.
- Insulated doors and gates: 0.25 kilograms per m².
- Sealing foam: 500 grams per kilogram of product.
- Extruded polystyrene for insulation: 2.5 kilograms per m³.
- Panels for cold stores and freezers: 6 kilograms per m³.
- Milk cooling tanks, indirect cooling system: 1 kilogram for each unit of cooling capacity expressed in kW.
- Milk cooling tanks, direct expansion system: 2 kilograms per unit of cooling capacity expressed in kW.